Ask Paul | National Electrical Code

By Paul W. Abernathy

Listen to a podcast, please open Podcast Republic app. Available on Google Play Store and Apple App Store.


Category: Courses

Open in Apple Podcasts


Open RSS feed


Open Website


Rate for this podcast

Subscribers: 2
Reviews: 0
Episodes: 249

Description

Welcome to Ask Paul the podcast where nationally recognized electrical code experts answer your electrical code-related questions on a weekly podcast. Join us as we answer questions submitted on the www.PaulAbernathy.com website. Get answers from National Electrical Code Panel Members who give their own opinions to answering NEC-related questions.

Please be sure to visit www.FastTraxTube.com and subscribe for a FREE ACCOUNT to listen to all our new podcasts starting March 1, 2024.

Become a supporter of this podcast: https://www.spreaker.com/podcast/ask-paul-national-electrical-code--4971115/support.

Episode Date
Ask Paul | Ground Rods and Light Poles
May 10, 2024
Let’s Ask Paul | Episode 179| Multiple Circuits and EGCs and Feeder Disconnect Ratings
May 05, 2024
Let’s Ask Paul | Episode 178| 2023 NEC Optional Method Calculation for Schools 220.86
May 01, 2024
Let’s Ask Paul | Episode 177| Transformer Loading and Basic Ampacity Calculations
Apr 30, 2024
Let’s Ask Paul | Episode 176 | How to Find the Horsepower Using Formulas
Apr 30, 2024
Let’s Ask Paul | Episode 175 | How to Find the Amps Using Formulas
Apr 29, 2024
Let’s Ask Paul | Episode 174 | Series and Parallel Combination Calculations
Apr 29, 2024
Let’s Ask Paul | Episode 173 | Parallel Circuit Formula Calculations
Apr 29, 2024
Let’s Ask Paul | Episode 172 | Series Circuit Formula Calculations
Apr 28, 2024
Let’s Ask Paul | Episode 171 | Ohms Law Formula’s Explained
Apr 28, 2024
Ask Paul | Existing Loads vs New Calculations
Apr 24, 2024
Let’s Ask Paul | Episode 170 | Optional Method Calculations for All Electric Restaurant
Apr 21, 2024
Let’s Ask Paul | Episode 169 | Accounting for EVSE Loads in Calculations 2023 NEC
Apr 21, 2024
Let’s Ask Paul | Episode 168 | Specific Luminaire Locations – Wet, Damp, Bathtubs, Etc.
Apr 21, 2024
Let’s Ask Paul | Episode 167 | Reidentification of Grounded Conductors in Multiconductor Cables
Apr 21, 2024
Let’s Ask Paul | Episode 166 | Receptacles in Islands, Extra Circuits to Garage, and Texas Masters Calcs
Apr 21, 2024
Ask Paul | Load Calculations
Apr 09, 2024
Ask Paul | Table 250.66 vs. 250.66(A),(B), and (C)
Mar 27, 2024
Ask Paul | Success Rate & Study Habits
Mar 19, 2024
Let’s Ask Paul | Episode 165 | Water Piping System Bond, Ground Rods, and CMECP
Mar 15, 2024
Ask Paul | GFCI's and Tankless Water Heaters
Mar 06, 2024
Ask Paul | AFCI EXTENSION
Mar 05, 2024
Ask Paul | How I Feel About Tik Tok
Feb 20, 2024
Let’s Ask Paul | Episode 164 | Basement GFCI’s, Adjustments and Corrections, and More
Feb 19, 2024
Let’s Ask Paul | Episode 163 | Multiple Service Cabinets and Single Water Pipe Riser
Feb 19, 2024
Ask Paul | Basic vs Enhanced NEC Course
Feb 12, 2024
Let’s Ask Paul | Episode 162 | Service Changes and Smoke Alarm Updates?
Feb 08, 2024
Sparky Mafia Podcast | 2029 NEC Restructuring Why Now?
Feb 08, 2024
Ask Paul | Motors and Nameplates
Feb 05, 2024
Let’s Ask Paul | Episode 161 | Multifamily Services and Service Disconnects
Feb 04, 2024
Let’s Ask Paul | Episode 160| HVAC Question and Nameplates
Feb 04, 2024
Ask Paul | Sizing the GEC when Meter Main Combo
Jan 17, 2024
Ask Paul | National Electrical Code
Jan 11, 2024
Ask Paul | Texas Electrical Exemptions
Jan 10, 2024
Ask Paul | How Long Should I Study?
Jan 09, 2024
Ask Paul | Fire Pump Question
Jan 04, 2024
Ask Paul | Optional Method Heating Loads
Dec 29, 2023
Ask Paul | SE-U and NM Cable
Dec 27, 2023
Let’s Ask Paul | Episode 159| Jumper with Parallel Neutral and Multiple Services on One Building
Dec 10, 2023
Let’s Ask Paul | Episode 158| Enclosures vs Cabinets vs Article 312 or Article 314
Nov 27, 2023
Let’s Ask Paul | Episode 157| EMT and Enphase, Bundled MC, Bonding Nipples, and Generators
Nov 26, 2023
Let’s Ask Paul | Episode 156| What is an Outlet? Boxes, Enclosures, or Just a Point on the System?
Nov 25, 2023
Let’s Ask Paul | Episode 155| Talking Taboo Range Calculations
Nov 25, 2023
Ask Paul | National Electrical Code
Nov 13, 2023
Ask Paul | National Electrical Code
Nov 10, 2023
Let’s Ask Paul | Episode 154| Garage Receptacles, Bathroom Receptacles, EV’s Again, and More.
Nov 01, 2023
Ask Paul | National Electrical Code
Oct 30, 2023
Ask Paul | National Electrical Code
Oct 27, 2023
Ask Paul | Discuss Continuous Loads
Oct 24, 2023
Let’s Ask Paul | Episode 153 | Can you parallel EGC’s in a single raceway or cable tray?
Oct 17, 2023
Let’s Ask Paul | Episode 152 | Multiple meters, neutrals at RV Parks, AHJ, motor overloads.
Oct 16, 2023
Let’s Ask Paul | Episode 151 | MC Supports, Digital Electricity, MC and Heavy Timber
Oct 16, 2023
Let’s Ask Paul | Episode 150 | Neutral Reduction Changes in 2020 NEC vs 2023 NEC
Oct 16, 2023
Ask Paul | AFCI and My Thoughts
Oct 13, 2023
Ask Paul | National Electrical Code
Oct 05, 2023
Ask Paul | Engraving Business (FACTS)
Oct 04, 2023
Ask Paul | Current Carrying Conductors
Sep 29, 2023
Ask Paul | CMECP Questions
Sep 27, 2023
Ask Paul | Tray Cable Questions
Sep 21, 2023
Ask Paul | Meg Testing
Sep 20, 2023
Ask Paul | Surge Protection Devices
Sep 06, 2023
Ask Paul | Generator Loads
Sep 01, 2023
Ask Paul | National Electrical Code
Aug 30, 2023
Let’s Ask Paul | Episode 149 | Storage Water Heater Overcurrent Protection and Conductor Sizing
Aug 26, 2023
Let’s Ask Paul | Episode 148 | Neutral Conductor Size Reductions and Prohibited Reductions
Aug 26, 2023
Let’s Ask Paul | Episode 147 | Cables and Connectors, EGC’s in Raceways, and DW and Disposer Together
Aug 26, 2023
Ask Paul | An Online Presence is VITAL!
Aug 25, 2023
Ask Paul | Handling Trolls..LOL
Aug 22, 2023
Let’s Ask Paul | Episode 146 | Explaining 230.85 and Emergency Disconnects
Aug 19, 2023
Ask Paul | Thoughts on Tik Tok
Aug 18, 2023
Let’s Ask Paul | Episode 145 | Sizing Wireways for Same Size and Random Size Conductors
Aug 14, 2023
Let’s Ask Paul | Episode 144 | Skin Effect in 60 Hz and Career Motivation Folks
Aug 14, 2023
Let’s Ask Paul | Episode 143 | Let’s Talk MC Cable and some Q and A on Metal-Clad
Aug 14, 2023
Let’s Ask Paul | Episode 142 | What’s MY favorite change to the 2023 NEC?
Aug 12, 2023
Let’s Ask Paul | Episode 141 | Stop Guessing Folks -Here are FACTS about NM Cable
Aug 12, 2023
Let’s Ask Paul | Episode 140 | Ready to be your own boss | Well let’s chat a bit first!
Aug 12, 2023
Let’s Ask Paul | Episode 139 | Panelboards and Number of devices and EVSE Chargers
Aug 05, 2023
Ask Paul | 310.12 Explained
Aug 02, 2023
Ask Paul | Change Your Image
Aug 01, 2023
Let’s Ask Paul | Episode 138 | Explaining High-Legs and Transformers
Jul 29, 2023
Ask Paul | National Electrical Code
Jul 28, 2023
Ask Paul | National Electrical Code
Jun 29, 2023
Let’s Ask Paul | Episode 137 | Can you give me any advice on managing my projects?
Jun 28, 2023
Let’s Ask Paul | Episode 136 | Paul disagrees AGAIN with NECA’s QOD “Charlie.”
Jun 28, 2023
Let’s Ask Paul | Episode 135 | White/Gray for 120/208 or 277/480 and Parallel MC’s and the EGC
Jun 28, 2023
Let’s Ask Paul | Episode 134 | Can you take a Red Conductor and Phase Color it Blue?
Jun 28, 2023
Ask Paul | National Electrical Code
Jun 27, 2023
Let’s Ask Paul | Episode 133 | Electrical Exam Question from Failed Exam
Jun 25, 2023
Let’s Ask Paul | Episode 132 | Grounding Requirements, if any, at Bus Shelters
Jun 25, 2023
Let’s Ask Paul | Episode 131 | Single Gang Nail-up’s – Tabs or Clamps
Jun 25, 2023
Let’s Ask Paul | Episode 130 | Can you MEG at 1000V on 600V Conductors?
Jun 16, 2023
Let’s Ask Paul | Episode 129 | PVC Raceway with Rigid Metal Conduit Transitions
Jun 16, 2023
Let’s Ask Paul | Episode 128 | What Grounding and Bonding Violation do you see the most?
Jun 04, 2023
Let’s Ask Paul | Episode 127 | Final Debate on Back Stabs and Wagos
Jun 04, 2023
Let's- Ask Paul Mobile | National Electrical Code
May 24, 2023
Let's Ask Paul | Episode 126 | Neutrals as Current Carrying Conductors
May 24, 2023
Let's Ask Paul | Episode 125 | Please explain 310.12(A) through (D) Again
May 02, 2023
Let's Ask Paul | Episode 124 | Explain Room Air Conditioners and Branch Circuits
May 02, 2023
Ask Paul | National Electrical Code
Apr 25, 2023
Let's Ask Paul | Episode 123 | GEC and Ferrous Raceways, more than 90-degree bends and Wago’s
Apr 11, 2023
Mobile Ask Paul | Paul's Opinion on Wago's and More
Apr 06, 2023
Mobile Ask Paul | How To Cheat on Exam
Apr 04, 2023
Mobile Let's Ask Paul | National Electrical Code
Mar 27, 2023
Let's Ask Paul | Episode 122 | Multipole GFCI in Old Homes and EV Chargers on NM Cable.
Mar 26, 2023
Let's Ask Paul | Episode 121 | Exam Troubles – I failed by only a few points. HELP
Mar 26, 2023
Let's Ask Paul | Episode 120 | Service Disconnects, Stair Butler, and Website Changes
Mar 26, 2023
Ask Paul | National Electrical Code
Mar 21, 2023
Ask Paul | National Electrical Code
Mar 14, 2023
Let's Ask Paul | Episode 119 | Motors, Main Breakers and Subs, LEDs in Closets, and Stiff NM Cable
Mar 08, 2023
Let's Ask Paul | Episode 118 | Random NEC Questions Submitted via Portal
Mar 04, 2023
Let's Ask Paul | Episode 117 | 2023 NEC Changes to Article 90, 100, and 110
Mar 04, 2023
Ask Paul | National Electrical Code
Feb 14, 2023
Ask Paul | National Electrical Code
Feb 13, 2023
Let's Ask Paul | Episode 116 | Reversing XFMR’s, FMC in Wet or Damp Locations, and Two Kitchens
Feb 12, 2023
Let's Ask Paul | Episode 115 | Drilling Enclosures, Motor Overload Protection, and PV EGC and GEC
Feb 12, 2023
Let's Ask Paul | Episode 114 | So answer some question about knob and tube expansion.
Feb 06, 2023
Let's Ask Paul | Episode 113 | Hey Paul – Give me the Long-Winded Bonding Bushing Lesson
Feb 06, 2023
Let's Ask Paul | Episode 112 | So what is the difference between 310.15(B)(1) and (B)(2)
Feb 03, 2023
Let's Ask Paul | Episode 111 | Single Family Dwellings – Overview of Standard Calculations
Jan 29, 2023
Let's Ask Paul | Episode 110 | Article 430 Motor Key Topics for Electrical Exams
Jan 29, 2023
Let's Ask Paul | Episode 109 | NM Cables and Electrical Inspectors Quandaries
Jan 29, 2023
Let's Ask Paul | Episode 108 | Explaining 10-second transfer for EES Type 1 Emergency
Jan 29, 2023
Ask Paul | National Electrical Code
Jan 19, 2023
Ask Paul | National Electrical Code
Jan 16, 2023
Ask Paul | National Electrical Code
Jan 11, 2023
Ask Paul | National Electrical Code
Jan 03, 2023
Let's Ask Paul | Episode 107 | 250.97 and 120/208V question and aluminum raceways and 250.64(E)(1)
Jan 01, 2023
Ask Paul | National Electrical Code
Dec 29, 2022
Ask Paul | National Electrical Code
Dec 22, 2022
Let's Ask Paul | Episode 106 | Fact or Fiction regarding NM Cables [bundles] in Cabinets
Dec 18, 2022
Let's Ask Paul | Episode 105 | Overload Rules for Non-Continuous Duty Motors and 60°C Terminals
Dec 18, 2022
Let's Ask Paul | Episode 104 | Transfer for optional standby, panels in cabinets, and Wire Integrity
Dec 14, 2022
Let's Ask Paul | Episode 103 | Does 702.4(B)(2)(a) and (b) apply to 706 for ESS?
Dec 14, 2022
Let's Ask Paul | Episode 102 | How old is too old to become an electrician?
Dec 11, 2022
Let's Ask Paul | Episode 101 | Thoughts on Starting an Electrical Business
Dec 11, 2022
Ask Paul | National Electrical Code
Nov 29, 2022
Let's Ask Paul | Episode 100 | Paul helps motivate an electrical worker to get licensed
Nov 25, 2022
Let's Ask Paul | Episode 99 | Paul explains commercial calculations and the Step Process
Nov 25, 2022
Let's Ask Paul | Episode 98 | Paul explains the elements to passing an electrical exam
Nov 25, 2022
Let's Ask Paul | Episode 97 | Paul explains the structural change to 210.12 AFCI’s for 2023 NEC
Nov 23, 2022
Let's Ask Paul | Episode 96 | Let’s talk Dimmers in stairways and Redundancies in Patient Care Spaces
Nov 23, 2022
Ask Paul | National Electrical Code
Nov 22, 2022
Ask Paul | National Electrical Code
Nov 21, 2022
Let's Ask Paul | Episode 95 | Explaining Tables 310.15(B)(1) vs (B)(2) and Pull Box Issues
Nov 20, 2022
Let's Ask Paul | Episode 94 | Licensing, Bundling NM Cable, and NM in Raceway
Nov 20, 2022
Ask Paul | Final days before the electrical exam, What now?
Nov 17, 2022
Let's Ask Paul | Special Personal Edition
Nov 14, 2022
Let's Ask Paul | Episode 93 | Explaining 410.2 and 410.16 Clothes Closet Luminary Locations
Nov 06, 2022
Let's Ask Paul | Episode 92 | Explaining 410.10(D) and Shower and Tub Spaces
Nov 06, 2022
Let's Ask Paul | Episode 91 | Office Buildings and Receptacles Question
Nov 04, 2022
Ask Paul | National Electrical Code
Nov 03, 2022
Ask Paul | National Electrical Code
Oct 31, 2022
Let's Ask Paul | Episode 90 | Explaining TradiesAPPS™ Mobile Business Apps
Oct 30, 2022
Ask Paul | National Electrical Code
Oct 27, 2022
Special Ask Paul | National Electrical Code
Oct 26, 2022
Let's Ask Paul | Episode 89 | Paul Explains PV Supply Side Connections
Oct 25, 2022
Let's Ask Paul | Episode 88 | Paul Explains AC vs DC Coupled Multi-mode Inverters
Oct 25, 2022
Let's Ask Paul | Episode 87 | Paul Explains load side 705.12(B)(1) and Feeders
Oct 25, 2022
Let's Ask Paul | Episode 86 | PV and Feed-Through Panels.
Oct 25, 2022
Let's Ask Paul | Episode 85 | HVAC Conductor Sizing Question– NECA
Oct 25, 2022
Let's Ask Paul | Episode 84 | GEC or EGC to rebar at separate structure – NECA
Oct 25, 2022
Let's Ask Paul | Episode 83 | Sizing the Grounding Electrode Conductor to a UFER (CEE) Ground
Oct 19, 2022
Let's Ask Paul | Episode 82 | Different System Voltages in the same Raceway Question
Oct 19, 2022
Let's Ask Paul | Episode 81 | Terminal Limitations and using 110.14(C)(1) Question
Oct 19, 2022
Ask Paul | National Electrical Code
Oct 11, 2022
CODE IN 5 Minutes | EP23 | Ampacity of Conductors in Auxiliary Gutters
Oct 08, 2022
CODE IN 5 Minutes | EP22 | Number of Conductors in Auxiliary Gutters
Oct 08, 2022
CODE IN 5 Minutes | EP21 | NM Cables bundled into cabinets – Again!
Oct 08, 2022
CODE IN 5 Minutes | It's Back Baby | EP 20 | Wake Up Facebook Code Guru's
Oct 08, 2022
Let's Ask Paul | Episode 80 | two weeks before your electrician exam study plan
Sep 25, 2022
Fast Trax® Enterprise Accounts | Electrical Contractor Program for Electricians
Sep 10, 2022
Let's Ask Paul | Episode 79 | 310.15(b)(1) vs 310.15(b)(2), GFCI Specific Appliance, Another Pool Question
Sep 06, 2022
Let's Ask Paul | Episode 78 | Equipotential bonding grid and Multifamily dwellings questions
Aug 29, 2022
Let's Ask Paul | Episode 77 | Portable Generators, Sizing Parallel EGC, and Dissection of Questions
Aug 20, 2022
Let's Ask Paul | Episode 76 | Voltage Drop Why, HCF Receptacle Locations, and Myers Hubs
Aug 07, 2022
Let's Ask Paul | Episode 75 | Number of branch circuits on 15 or 20 and more.
Aug 03, 2022
Let's Ask Paul | Episode 74 | Cabin Disconnects, GFCI and Dryer Issue, and Lutron Panels
Aug 03, 2022
Let's Ask Paul | Episode 73 | SEU and Bare Conductors and Rods at Detached Structure
Jul 25, 2022
Let's Ask Paul | Episode 72 | Can GFCI's protect circuits with no EGC to Receptacles?
Jul 16, 2022
Let's Ask Paul | Episode 71 | WR on USB Devices, Apology OK, Raceway Studs and more
Jul 16, 2022
Let's Ask Paul | Episode 70 | 12 AWG and its amps, Motor Tables, and More
Jul 09, 2022
Let's Ask Paul | Episode 69 | Helping answer a Real World Transformer Sizing Request
Jul 04, 2022
Let's Ask Paul | Episode 68 | Verifying an Electrician's Code References for Fire Incident
Jun 26, 2022
Let's Ask Paul | Episode 67 | (2) 100A Panels supplied by 125A Main & More
Jun 26, 2022
Let's Ask Paul | Episode 66 | Metal Boxes and Equipment Bonding Jumper Question
Jun 19, 2022
Let's Ask Paul | Episode 65 | Paul and Special Guest Jay Talk Schneider Recall
Jun 17, 2022
Let's Ask Paul | Episode 64 | So you wanna be a Electrical Inspector
Jun 11, 2022
Let's Ask Paul | Episode 63 | Ampacity of NM Cable and Subby's Bruh at Detached Garages
Jun 11, 2022
Let's Ask Paul | Episode 62 | Questions on Exam Prep, Neutral Colors, and Temporary NM Cable
May 20, 2022
Let's Ask Paul | Episode 61 | Sizing Conductors to AC Motor Compressor
May 14, 2022
Let's Ask Paul | Episode 60 | Explaining Transformer Protection in 450.3(B)
May 14, 2022
Let's Ask Paul | Episode 59 | Understanding 150V or less to ground and 150V or more to ground
May 08, 2022
Let's Ask Paul | Episode 58 | Receptacle Spacing, Bus Ratings, and Ranges
May 08, 2022
Let's Ask Paul | Episode 57 | Conductors at Subby's Bruh and Straight/Slash Rated Breakers
May 02, 2022
Let's Ask Paul | Episode 56 | Our Present and Future Students - You Are Why We Do This!
Apr 25, 2022
Let's Ask Paul | Episode 55 | Why we don't just drive ground rods everywhere, like for Receptacles
Apr 25, 2022
Let's Ask Paul | Episode 54 | Three Gang and Larger Box Support and More
Apr 25, 2022
Let's Ask Paul | Episode 53 | Wago's and BackStabbing....Ok Haters....LOL
Apr 17, 2022
Let's Ask Paul | Episode 51 | Multiwire Branch Circuits, Pigtails, and Listed Wall Mounted Devices
Apr 17, 2022
Let's Ask Paul | Episode 50 | Dedicated Equipment Space and Raceways Aboveground on Earth
Mar 29, 2022
Let's Ask Paul | Episode 49 | Will electrical courses help folks who are not electricians?
Mar 29, 2022
Let's Ask Paul | Episode 48 | Getting NM-B Into an Exterior Panel and Neutral Sizing Question
Mar 12, 2022
Let's Ask Paul | Episode 47 | When Counting Neutrals as Current Carrying Conductors
Feb 24, 2022
Let's Ask Paul | Episode 46 | GEC's in Metal Raceways and PVC Boxes
Feb 24, 2022
Let's Ask Paul | Episode 45 | GFCI's and Doorways and Growing Your Business Advice
Feb 24, 2022
Let's Ask Paul | Episode 44 | Electrical Conductor Ampacity Question
Feb 13, 2022
Let's Ask Paul | Episode 43 | Electrical Exam Assumptions and AFCI's on Service Updates
Feb 12, 2022
Let's Ask Paul | Episode 42 | Single Family Dwelling Calculation -Summary
Feb 12, 2022
Let's Ask Paul | Episode 41 | Wall Space or Raised Floor and Daisy Chain Luminaries
Feb 03, 2022
Let's Ask Paul | Episode 40 | Electrical In Flood Zones - My Thoughts and FEMA
Feb 03, 2022
Let's Ask Paul | Episode 39 | 312.2 versus 314.15 | Damp and Wet Locations
Feb 03, 2022
Let's Ask Paul | Episode 38 | 10' Tap Rule Explained
Jan 22, 2022
Let's Ask Paul | Episode 37 | Supplemental Electrodes Explained
Jan 15, 2022
Let's Ask Paul | Episode 36 | 310.12 Explained as requested on Ask Paul
Jan 15, 2022
Let's Ask Paul | Episode 35 | 210.12(D), Double Lugging, and Electrical Inspector Advice
Jan 03, 2022
Let's Ask Paul | Special Episode | Explaining the Fast Trax® System Question
Dec 29, 2021
Let's Ask Paul | Episode 34 | AFCI Receptacles and Bedrooms Question
Dec 29, 2021
Let's Ask Paul | Episode 33 | Can you explain 230.40 Exceptions
Dec 24, 2021
Let's Ask Paul | Episode 32 | NM-B in a Raceway in Unfinished Basement
Dec 21, 2021
Let's Ask Paul | Episode 31 | What did I use to bore under sidewalks - TIPS
Dec 20, 2021
Let's Ask Paul | Episode 30 | Supply-Side Objectionable Current and Concerns
Dec 18, 2021
Let's Ask Paul | Episode 29 | Manual Transfer Switch and 705.11 Question
Dec 12, 2021
Let's Ask Paul | Episode 28 | Metal plates or sleeves for MC Cable in Metal Studs?
Nov 25, 2021
Let's Ask Paul | Episode 27 | Understanding Receptacle Ratings for 15 and 20 Amp Circuits
Nov 23, 2021
Let's Ask Paul | Episode 26 | Calculating Minimum General Use Lighting and Receptacle Branch Circuits
Nov 23, 2021
Let's Ask Paul | Episode 25 | Pull Box and Junction Box Calculation Overview
Nov 23, 2021
Let's Ask Paul | Episode 24 | Let's Settle The Box Cover Debate - Are They Required?
Nov 13, 2021
Let's Ask Paul | Episode 23 | So Your Code Knowledge is Good - But Need More Tips!
Nov 13, 2021
Let's Ask Paul | Episode 22 | Old Homes with No Equipment Grounding Conductors
Nov 13, 2021
Let's Ask Paul | Episode 21 | Someone asks an exam question and if GFCI and AFCI exists for whole house
Oct 31, 2021
Let's Ask Paul | Episode 20 | Raceways Supporting Cables & GFCI's and MIniSplits
Oct 31, 2021
Let's Ask Paul | Episode 19 | Explain The Types of Bonding Jumpers
Oct 15, 2021
Let's Ask Paul | Episode 18 | When can I use Table 310.12 for service and feeder sizing?
Sep 11, 2021
Let's Ask Paul | Episode 17 | Can THHN/THWN-2 be installed in cable trays?
Sep 11, 2021
Let's Ask Paul | Episode 16 | Does the two to six disconnect rule still exist?
Sep 11, 2021
Let's Ask Paul | Episode 15 | Type NM-B Outside and Type MC Outside Facts
Sep 11, 2021
Lets Ask Paul | Episode 14 | Raceway Supported Enclosures & GFCI in Garages
Sep 01, 2021
Lets Ask Paul | Episode 13 | Please explain supplemental grounding electrodes
Aug 22, 2021
Lets Ask Paul | Episode 11 | Supply Side Connections for PV Question
Aug 22, 2021
Lets Ask Paul | Episode 10 | How 240V Circuit Works and Sizing a feeder grounded conductor
Aug 08, 2021
Lets Ask Paul | Episode 9 | Overhead, Underground, Service Entrance Conductor Sizing
Jul 18, 2021
Lets Ask Paul | Episode 8 | Ufer Electrodes, Secondary Conductors, and Fast Trax
Jul 18, 2021
Lets Ask Paul | Episode 7 | Paul's Response to an EC&M Article called Microwave Madness
Jul 10, 2021
Lets Ask Paul | Episode 6 | Questions submitted via PaulAbernathy.com- Basements, Etc.
Jul 10, 2021
Lets Ask Paul | Episode 5 | Please explain the CMECP® Certification Program for Electricians
Jul 05, 2021
Let's Ask Paul | Episode 4 | Tapping a Tap and Ambient Correction Questions
Jul 04, 2021
Let's Ask Paul | Episode 3 | Electrician Questions and the NEC
Jul 04, 2021
Let's Ask Paul | Episode 2 | Electrician Questions and the NEC
Jun 13, 2021
Let's Ask Paul | Episode 1 | Introduction to Ask Paul and www.PaulAbernathy.com
Jun 13, 2021